Filter Results By:

Products

Applications

Manufacturers

Showing results: 7531 - 7545 of 17066 items found.

  • Data Collection

    Davis Instruments Corp.

    Data collection is the heart and soul of weather monitoring and prediction. Weather station data collection can use either wired or wireless systems, and Davis Instruments has a range of transmitters, receivers, and data access options to help you transmit data to your personal system or larger groups. You can upload data only to your Vantage Pro2 or Vantage Vue console, or you can choose to also upload to WeatherLink.com where your data can be accessed on your phone or computer.

  • Hipot Testers

    Hypot® Series - Associated Research

    The Hypot Series sets the standard for safety and efficiency in production line Hipot Testing. Whether your application requires AC Withstand tests, DC Withstand tests, or Insulation Resistance tests, The Hypot Series provides innovations that will allow you to begin achieving best practices for safety and efficiency without the need for an expensive automated test system or connection to a PC. You can even connect the Hypot Series with the HYAMP Series to form a seamless safety compliance system for Hipot and Ground Bond Testing.

  • NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module

    780968-01 - NI

    500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.

  • NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module

    780968-02 - NI

    500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.

  • NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module

    785041-01 - NI

    500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.

  • PCI-8361, PCI Host, 100 MB/s, Copper Cable MXI-Express Device for PXI Remote Control

    781394-01 - NI

    The PCI‑8361 is an MXI‑Express remote controller for devices or systems over cabled PCI from a computer with a PCI slot. The PCI‑8361 card provides a PCI link over a copper cable to the PXI‑8360 remote control module when used for PXI system control. This link is transparent to software applications and drivers, so computers and servers can control connected devices with no additional programming. With NI remote controllers, PXI modules can be used as if they are PCI devices directly installed in the computer.

  • Multi-Wavelength Meter

    86122C - Keysight Technologies

    With an absolute wavelength accuracy of 0.2 ppm and 0.15 ppm differential accuracy, the new Keysight 86122C Multi-Wavelength Meter belongs in the top class of wavelength meters available for optical communication testing. Its wavelength range of 1270 to 1650 nm covers all fiber-to-the-home, metro and long-haul transmission systems. The instrument can measure the spectra of up to 1,000 laser lines at once, which is more than sufficient for fully populated dense-wavelength-division multiplexed systems (DWDM).

  • Laser Heads

    Keysight Technologies

    The laser head is the source of the laser beam used in all laser motion and position measurement systems. The primary difference between laser heads is in the velocity, reference frequency and optical output power. Other considerations are size, heat dissipation, and input power requirements. Which laser you choose depends primarily on the application in which it will be used. For example, semiconductor lithography systems typically have faster moving parts (stages), and therefore need higher velocities than machine tool applications.

  • PCIe-1477, 80-Bit Camera Link, PoCL-Compatible Frame Grabber Reconfigurable Device

    786502-01 - NI

    The PCIe-1477 works well for deployment systems and features a user-programmable FPGA for onboard image processing. Placed directly in the image path, FPGAs can acquire and process images with closed-loop control without CPU intervention. This technology is also suitable for high-throughput system architectures to preprocess image data on the FPGA and then send the data to the CPU for further processing and decision-making. The PCIe-1477 also supports Power over Camera Link (PoCL), which you can use to power cameras through PoCL-enabled cables.

  • Rework

    SUMMIT Rework Systems - VJ Electronix, Inc.

    With the largest installed base of rework systems in the world, VJ Electronix is confident that we can meet any rework need that you have. Our systems are designed to rework components ranging from 01005 all the way to 120mm and we have a large range of applications including connectors, package-on-package, RF shields, and more! High-level automation, intuitive software, and easy set up help minimize operator intervention and simplify your most difficult rework processes.

  • Drop Testers

    Lansmont Corporation

    This process is vital for ensuring that products travel to customers safely and securely, eventually arriving damage free. In turn, drop test systems help companies save money and maintain positive brand-owner reputations by helping to design packaged products that will deliver products with their intended inherent quality intact. Lansmont Drop Test Systems are the gold standard for accurate and repeatable drop testing. Every drop tester we manufacture is factory-tested to ensure it meets flatness-of-drop requirements and exceeds industry specifications.

  • PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module

    782835-37 - NI

    256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.

  • NI-9218, 51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module

    783362-01 - NI

    51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module - The NI‑9218 is designed for multipurpose measurements. It offers built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. Each channel is individually selectable, so you can perform different measurements on each channel. The NI‑9218 is ideal for creating universal test systems for automotive, off-highway, and data-logging systems.

  • PXIe-2738 , 256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module

    782835-38 - NI

    256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.

  • NI-9218, 51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module

    783367-01 - NI

    51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module - The NI‑9218 is designed for multipurpose measurements. It offers built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. Each channel is individually selectable, so you can perform different measurements on each channel. The NI‑9218 is ideal for creating universal test systems for automotive, off-highway, and data-logging systems.